<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-20 20-37-33
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.10 MHz 5/5, 61 dBuV CLASSIQ
Pilot RDS Phase Difference
7.1 kHz 3.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
9 kHz 71 kHz 10060 0,0000
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
1,3 dBr 2,22 dBr 3,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"CLASSIQ " F221 0 (No PTY) 1 0 1 2 20:37, 20.01.2025
RT
"Geiger : Valse de Ferdinand - Orch Philh Vienne, R. Muti (2025)."
AF EON
87.6, 87.8, 88.2, 88.3, 88.5, 88.6, 90.8, 92.9, 94.5, 94.9, 96.5, 98.7, 99.0, 99.9, 100.9, 101.1, 101.4, 103.0, 106.1, 106.4, 107.3 MHz -
FM Scope Station: 101.10 MHz, signal: 5/5 (61 dBuV) Max at: 71 kHz MIN: 9 kHz % above 75 kHz: 0,0000 Acquired: 2025/01/20 20:36:29 Total samples: 10060 Equivalent time: 0:08:23 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 3,4 dBr MIN: 1,3 dBr AVE: 2,22 dBr % above 10,0 dBr: 0,0 Last value: 1,9 dBr (2025/01/20 20:36:29) Station: 101.10 MHz, signal: 5/5 (61 dBuV) 20:30 20:31 20:32 20:33 20:34 20:35 20:36 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr] 0 5 Signal Quality